Characteristics of High Temp. Insulation and Sheath Materials

Designation Electrical
VDE initial-code Abbre-viations Materials Density Break down voltage Specific volume resistivity Dielectric-constant Dielectric loss factor tan δ
g/cm3 KV/mm (20°C) Ohm·cm 20°C 50 Hz/20°C
10Y PVDF Polyvinylidene fluoride 1,7–1,9 25 1014 9–7 1,4 x 10–2
7Y ETFE Ethylene-Tetrafluorethylene 1,6–1,8 36 1016 2,6 8 x 10–4
6Y FEP Fluorinated ethylene propylene 2,0–2,3 25 1018 2,1 3 x 10–4
5YX PFA Perfluoroalkoxypolymeric 2,0–2,3 25 1018 2,1 3 x 10–4
5Y PTFE Polytetrafluorethylene 2,0–2,3 20 1018 2,1 3 x 10–4
  E-CTFE Ethylene-Chlorotrifluoroethylene 1,67–1,69 39 1015 2.5 9 x 10–3

 

Designation

Thermic

VDE initial-code

Abbre-viations

Materials

Working temp

 

Melt-temp

 

Oxygen index LOI

Heating value H0

Thermal-conductivity

Corrosive gases in case of fire

Radiation resistance

Perma-nent (°C)

Short time(°C)

+°C

(% O2)

MJ·kg-1

W·K-1·m-1

Mrad

10Y

PVDF

Polyvinylidene fluoride

– 40+135

 

+160

>170

40–45

15

0,17

Hydrofluoric

10

7Y

ETFE

Ethylene-Tetrafluore-thylene

–100+150

 

+180

>265

30–35

14

0,24

Yes

10

6Y

FEP

Fluorinated ethylene propylene

–100+205

 

+230

>225

>95

5

0,26

Yes

1

5YX

PFA

Perfluoroa-lkoxypolymeric

–190+260

+280

>290

>95

5

0,21

Yes

0.1

5Y

PTFE

Polytetra-fluorethylene

–190+260

+300

>325

>95

5

0,26

Yes

0,1

 

E-CTFE

Ethylene-Chlorotri-fluoroethylene

–100+140

+170

>242

>60

14

0,14

YES

0.01

 

Designation Mechanical Halogen
VDE initial-code Abbre-viations Materials Tensile strength Elongation at break Shore hardness Water absorbtion Halogen-free
N/mm2 % %  
10Y PVDF Polyvinylidene fluoride 50–80 150 75–80 (D) 0,01 No
7Y ETFE Ethylene-Tetrafluorethylene 40–50 150 70–75 (D) 0,02
6Y FEP Fluorinated ethylene propylene 15–25 250 55–60 (D) 0,01
5YX PFA Perfluoroalkoxy-polymeric 25–30 250 55–60 (D) 0,01
5Y PTFE Polytetra-fluorethylene 80 50 55–60 (D) 0,01
  E-CTFE Ethylene-Chlorotri-fluoroethylene 48 200-300 75()D 0.1

 

Designation Properties
VDE initial-code Abbre-viations Materials Oxidation resistance Heat resis-tance Oil resis-tance Low-tempe-rature flexibility Weather, sun resistance Ozone resis-tance Abrasion resistance Flame resis-tance
10Y PVDF Polyviny-lidene fluoride O O E F E-O E E E
7Y ETFE Ethylene-Tetrafluore-thylene E E E E E E E G
6Y FEP Fluorinated ethylene propylene O O O O O E E O
5YX PFA Per-fluoroalkoxy-polymeric E E E E E E G E
5Y PTFE Polytetra-fluorethylene O O E-O O O O O E
  E-CTFE Ethylene-Chlorotri-fluoroethylene O O O O O E E E-O

 P = Poor; F= Fair; G = Good; E = Excellent; O = Outstanding

 

Designation Properties
VDE initial-code Abbre-viations Materials Water resis-tance Acid resis-tance Alkali resis-tance Aliphatic hydrocarbons resistance (Gasoline, kerosene, etc) Aromatic Halogenated hydrocarbons resistance (Degreaser solvents) Alcohol resis-tance
 
hydrocarbons resistance (Benzol, toluol, etc.)
10Y PVDF Polyviny-lidene fluoride E G-E E E G-E G E
7Y ETFE Ethylene-Tetrafluore-thylene E E E E E E E
6Y FEP Fluorinated ethylene propylene E E E E E E E
5YX PFA Per-fluoroalkoxy-polymeric E E E E E E E
5Y PTFE Polytetra-fluorethylene E E E E E E E
  E-CTFE Ethylene-Chlorotri-fluoroethylene E E E E E E E

P = Poor; F= Fair; G = Good; E = Excellent; O = Outstanding

 